Record · Aug. 2019

IT service ticket for a crashed surveillance RAID drive system, Aug. 2019

Service Request #24975

Raid just crashed

GF G-5-21

Additional Information & Custom Fields;

Detailed Description:

Raid is showing 2 “S”s on the display. is going to get new drives from computer services for the raid and replace them in the morning.

Schedule

EFTA00127470

Equipment - No Equipment

Comments

Comment

on Aug 14, 2019, 8:02 PM

[PRIVATE]

called us on Thursday August 8th stating that he had 2 bad drives on his raid unit of the NICE Vision Pro Unit NVR. We advised him to get replacement drives. Once they are replaced they should start to initialize to become available for the raid array. did not have drives readily available. He checked with his local CSM to see if they had any spare replacement drives. Once he located replacement drives on Friday August 9th, he did not have access to the DVR room to replace them. He called Signet for phone support on Saturday August 10th when he gained access to the DVR room. He attempted to replace the drives and they started to rebuild. During the rebuild process of the drives, the drives were required to be taken out of the raid on DVR 2. Once the drives are removed without proper shutdown of the recorder, the video database becomes corrupted. Typically, any time the raid on a raid 5 configuration loses 2 drives, the raid needs to be rebuilt and all data is wiped from the raid.

Comment

on Aug 8, 2019, 3:38 PM .

[PRIVATE]

Hi Jeff: Unable to locate anything official. The basic steps are as following: 1. Set the raid level to none, and save. It will restart with all drives being “J.” [Replace any faulty drives] 2. Set the raid level to 5 and save. It will restart and being an initialization. The password is

Assignment Created

on Aug 8, 2019, 3:36 PM

The assignment on Aug 8 - 16, all-day for

[PRIVATE]

will be working on this. Get a case started with Qognify.

Details - No Detail Items

EFTA00127471

IT service ticket for a crashed surveillance RAID drive system, Aug. 2019

Other records

DOJ Epstein Files, Data Set 9 · Aug. 2019

Service Request 24975 Raid just crashed GF G-5-21 Additional Information & Custom Fields; Detailed Description: Raid is showing 2 "S"s on the display. is going to get new drives from computer services for the raid and replace them in the morning. Schedule EFTA00127470 Equipment - No Equipment Comments Comment on Aug 14, 2019, 8:02 PM [PRIVATE] called us on Thursday August 8th stating that he had 2 bad drives on his raid unit of the NICE Vision Pro Unit NVR. We advised him to get replacement drives. Once they are replaced they should start to initialize to become available for the raid array. d…